SOURCE-LINKED INTELLIGENCE
Contact-Stable Deformable Tissue Simulation Using Implicit Integration and Live-Pose Grasp Constraints for Laparoscopic Surgery Robot Policy Evaluation
Closed-loop evaluation of surgical robots requires tissue that deforms, can be grasped and lifted, and reproduces the anatomy in which the robot will operate. We present a simulator in which this tissue is reconstructed from a fixed-view RGB-D recording of the surgical field, composited to remove the instruments, closed into watertight volumes and tetrahedralised; the pipeline was applied unchanged to three specimens of two species (thirteen organs, 146,061 tetrahedra, no inverted elements). For one specimen, the organs are placed in a bimanual cell in which two Franka FR3 arms operate motoris
Read original source ↗ Open in workspace
- recordType
- paper
- region
- Global
Evidence & attribution
- arXiv · AI, language, vision and robotics · 2026-09-22T03:52:24.000Z
First collected: 2026-09-23T04:21:13.910Z. This is not the publication date.